// Customer service+49 5221 9944770Mon–Fri 8–16 h
info@esdi.deDE
ESDI GmbH & Co. KG — workshop for Gildemeister CNC lathes
Request Consultation

// Component Category · Electrical & Sensor Parts

Gildemeister
Electrical & Sensors.
From Contactor to Encoder.

Gildemeister electrical and sensor spare parts: relays, contactors, fuses, power supplies, encoders, limit switches. 1,312 part numbers in the catalogue, since 1994. For CT, CTX, GDM, MD, TWIN and GMX.

“24V missing” is not a part — it's a clue.

Contactor hums, encoder reports a fault, reference point missing — with electrical and sensor problems the defect is rarely where the symptom shows up. Relay, cable, encoder or control?

// Electrical · all 793 parts

  • // Component faulty or burnt out
  • // Contactor won't engage
  • // Fuse keeps blowing
  • // Contact problems · loose connection
  • // No power at the control — Error code: 24V missing

// Sensors · all 519 parts

  • // Reference point not found
  • // Position error · dimensional deviation
  • // Encoder error message on the control
  • // Spindle orientation not working
  • // Backup battery weak — Error code: Battery low NC
Request Consultation Straight to a Technician Describe it in Writing

Reply within 24h · In person · No bots

Not sure which component is affected? Use our fault diagnosis — we measure before we replace.

Electrical & Sensor Components
for Gildemeister CNC.

ESDI supplies electrical and sensor spare parts for the Gildemeister machine family — from a single auxiliary contactor to a complete encoder wiring harness.

1,312 Part Numbers
to Look Up.

Gildemeister Electrical & Sensors
for Every Series.

What we often see
with electrical & sensor faults.

  1. // 01 · Contactor or Fuse?

    The Fuse Is Rarely to Blame.

    If the control cabinet hums and the contactor won't engage, the contactor coil is usually the culprit, not the fuse. Simply swapping the fuse without a diagnosis often achieves nothing.

  2. // 02 · Encoder Error Message

    Cable First, Then Encoder.

    “Reference point not found” can come from the encoder, the cable or the control. Check cables and connectors first — that often saves the expensive encoder replacement.

  3. // 03 · 24V Missing

    Power Supply or Just a Fuse?

    Component class: fuses, 24V power supply, bridge rectifier. Simply swapping the fuse without a diagnosis often leads to follow-up damage to the power supply. More on this error code.

  4. // 04 · Battery low NC

    Back Up Before Replacing.

    The backup battery on the main board is weak. Before any battery change, parameters and NC programs must be exported — otherwise you risk losing all of them. More on this error code.

Gildemeister Electrical & Sensors —
what workshop managers ask.

Which Gildemeister electrical and sensor parts does ESDI supply?

1,312 part numbers in two component groups: 793 electrical parts (relays, contactors, fuses, power supplies, fans) and 519 sensor parts (encoders, limit switches, proximity switches, cables). For CT, CTX, GDM, MD, TWIN and GMX.

What does the “24V missing” fault on the control mean?

The 24V supply for the PLC or the control has failed. Component class: fuses, 24V power supply or bridge rectifier. Every Gildemeister series is affected — CT, CTX, GDM, MD, TWIN, GMX.

What does “Battery low NC” mean on Heidenhain controls?

The NC backup battery on the main board is weak. It sounds harmless, but the next power cut can wipe out every parameter. Affected: Heidenhain EPL and EP controls, many CT/CTX/GDM.

What if the symptom cannot be pinned to one component?

Then guess-and-replace repair is not worth it. Our fault diagnosis measures signal, voltage and concentricity and links the symptom to the component — on site or narrowed down by phone.

// Straight to a Technician

Electrical or sensor problem?
Narrow it down first, then replace.

  • Reply within 24h on business days
  • Personally from a technician — no bots, no call centre
  • Your inquiry never leaves our workshop
05221 · 9944770

Workshop hotline · Mon–Fri 8am–4pm CET · 2–10 AM New York · 11 PM–7 AM Los Angeles · reply within 24h on business days

// Describe it in Writing

By sending you agree to our privacy policy.

Part Numbers to Look Up

Our workshop stock as a list — every number with a direct inquiry path.